ETAP Training In Bangalore
ETAP Training primary and overall objective of this course is to give a hands-on experience of Software Interface, Load Flow analysis, ARC Flash Analysis, Short Circuit Analysis, simulation, monitoring, control, optimization, and automation of electrical power systems.
Course Objectives
- Able to analysis, simulation, monitoring, control, optimization, and automation of electrical power systems.
- Able to work in Electrical Industries, Substation, ,Oil & Gas, Power Plant etc.
- Real-time Projects Execution.
Audience
- BE / Btech, ME / Mtech, Bsc, Msc, Phd,ITI, Diploma
- Working Professionals
Find Why We Are Unique ?
Course Overview
Powers System Basics | Sizing, Load Calculation, SLD |
---|---|
Analysis | Load Flow Analysis |
Analysis | Arc Flash Analysis |
Analysis | Short Circuit Analysis |
Analysis | Relay Cordination |
Dialux | Lighting Loads |
Course Feature
Course Duration | 1 Month |
Skill Level | Advance |
Duration | 1-3 HRS ( Class+Lab) |
Mode Of Training | Online | Offline |
Projects | Real Time Projects |
Certificate | Govt Affiliated, ISO, Global Certified |
Embedded Training Syllabus In Detail
- Overview: Transformer and Cable Sizing, Project Settings & One Line Diagram, Load Flow Study, Evaluation & Result Analyzer, Data Requirements, Configuration & Case Study Edit, Diversity / Demand Factors, Parameter Settings / Adjustments, Reports / Alerts, Result Analyzer, Exercise
Short Circuit Study: Evaluation & Result Analyzer, Data Requirements, Types of Short Circuit in IEC & Factors, Device Duty Calculation in Mesh & Non-Mesh Networks, Parameter Settings / Adjustments, Reports / Alerts, Result Analyzer, Exercises
AC Arc Flash Analysis & Result Analyzer: AC Arc Flash Concept & Overview, Data Requirements, PPE Requirements, Parameter Settings / Adjustments, Reports / Alerts, Result Analyzer, Arc Flash Labels, Exercises
Star-Protective Device Coordination / Selectivity: Data Requirements, Protection Equipment Library, Protection & Selectivity Concepts, Protective Device Arrangements, Time-Current Characteristics, Exercise
- Motor Modeling & Motor Start
- Motor Reacceleration Transients
Harmonics Studies & Filter Sizing: Data Requirements, Harmonic Source Modeling, Harmonic Library / Inter-Harmonics, Harmonic Load Flow / Frequency Scan, Parameter Settings / Adjustment, Reports / Alerts / Plots, Exercise
- Generator Model & Load Flow
- Unit Transformer Tap Optimization
- Transient Stability Analysis, Transient Stability Studies, Transient Generator Modeling,
Reliability Assessment Analysis, Data Requirements and Reliability Library, Study / Report Settings, Load Point and System Results, Reports and Display Options, Reliability Analysis Plots, Exercise
Optimal Capacitor Placement Analysis, Purpose of Shunt Capacitor Applications, Data Requirements, Optimal Capacitor Placement Capabilities, Display Results / Plots, Exercise
- Ground Grid Design, Data Requirements (Rod / Conductor), Regular / Irregular Ground Grid Modeling, Design Criteria, Reports / Alerts / 3D-Plots
- Generator Relative Angle , Generator Outage, Modelling of AVR & Governor
- DC System Studies Overview
- Introduction, Lighting Control Design & Calculation, Indoor Lighting, Outdoor Lighting,
- Projects , Assigments & Test
Ajay –
I have taken training online, I would like to thank trainer for providing me handson training in different analysis, relay cordination, cable sizing and lighting load calculation Thanks SI Team
Kushi –
I have 6 years of exp in power sector, I have persued this training for upgrading myself and thanks to team for providing handson training with load flow, arc flash and short circuit analysis